Camus Dynaforce Hydronic Condensing Boiler

Camus Dynaforce Series Condensing Boiler

The Camus Dynaforce Hydronic Condensing Boiler has an efficiency rating of up to 99% and features a stainless steel vertical cylindrical heat exchanger. The Dynaforce is available for Hydronic Heating or Domestic Hot Water with models ranging in size from 300,000 BTU to 5 million BTU with a turndown ratio of 5:1

 

Standard Features Include:

 

  • 18 models available with inputs ranging from 300,000 btu/hr to 5 Mil btu/hr
  • Up to 99% Thermal Efficiency
  • Suitable for Category 2 and Category 4 installation
  • All welded heat exchanger, 316L headers, 439 tubes, counter flow, vertical cylindrical construction
  • Return water temperatures down to 40°F
  • Single point input adjustment for control of air and gas
  • 1 to 1 air/gas ratio control for perfect combustion across entire modulation range
  • Extremely low NOx emissions (less than 9 ppm)
  • Flow Switch
  • Water pressure switch
  • Local/Remote switch for building management, remote modulation and set-point control
  • Extremely low noise level
  • Stainless steel mirror finish outer jacket
  • Advanced integrated Honeywell SOLA control with touch-screen interface
  • Suitable for venting with PVC, CPVC or PPE plastic vent material (app. dependent)
  • Cascade up to 8 individual appliances in daisy-chain formation
  • Direct ignition up to 2.5 million BTU/hr.
  • Proven pilot ignition for 3 to 5 million BTU/hr.
  • Low gas pressure switch
  • High Gas pressure switch (models 3000 through 5000)
  • Inlet regulator for incoming gas pressures up to 14” w.c.
  • Stainless steel burner with radial knitted fiber
  • Easy access to components for maximum serviceability
  • Maximum allowable working pressure of 160 psig
  • Maximum allowable discharge temperature of 210°F
  • Minimum gas pressure requirements of 4.5” w.c. for models 300-1000, 7” w.c. for models 1200-5000
  • Main burner test firing valve
  • For operation with natural gas or propane
  • Flame failure alarm contacts
  • 5:1 turndown ratio with a minimum 20% firing rate
  • Flue temperature monitoring

 

Optional Features Include:

 

  • Dual Fuel for firing with natural and propane (incl. two gas trains)
  • Pump delay up to 1hp/Pilot duty over 1hp
  • Air inlet damper and/or damper contacts
  • Low water cut off (manual or automatic reset)
  • High gas pressure switch (standard on models 3000-5000)
  • Status on/off monitoring contacts
  • Gateway protocol converter for BACnet, Metasys N2, IP or LonWorks
  • Neutralization kit for condensate water
  • Remote operation for set-point or fire-rate control utilizing 0-10VDC
  • Additional Voltages

 

 